Hexonic USA - Data Centers & Liquid Cooling
USA / DATA CENTERS & LIQUID COOLING

Move more heat.
Use less space.

Heat exchanger solutions for direct liquid cooling, CDU systems, immersion cooling and high-capacity central cooling plants.

Thermal infrastructure for AI and HPC

Cooling architectures built for higher rack density.

Select the heat exchanger around the cooling architecture, thermal duty, approach temperature, pressure drop and available footprint.

2-3 MWLF700 thermal capacity per exchanger in high-capacity CDU applications.
125 kWLC170 heat duty in immersion cooling applications.
1,200 kWRVD235LN case duty for demineralized-water cooling.
10-15 MWJAG plate-and-frame capacity in large central systems.
Three liquid-cooling architectures

Where the exchanger sits.

HEXONIC solutions cover the primary heat-transfer positions in modern data-center liquid-cooling systems.

CDU and direct liquid cooling

Transfer heat between the technical cooling system and facility water loop with compact, high-capacity brazed exchangers designed for low approach temperatures.

Rack and row scale

Immersion cooling

Remove heat from dielectric oil and transfer it to glycol or water circuits using compact brazed plate heat exchangers with controlled pressure drop.

Tank and module scale

Central plant and free cooling

Connect technical and facility water systems, support very high flow rates and increase the operating window for economized cooling.

Facility scale
Four formats

One thermal strategy.

Four exchanger formats for the main liquid-cooling duties, from compact CDUs to central cooling plants.

01

LF700

CDU

Large-format fully brazed plate heat exchanger for high-capacity CDU modules and low-approach liquid cooling.

L Series
02

LC170

Immersion

Compact oil-to-glycol brazed exchanger for immersion-cooling loops and high heat duties with controlled pressure drop.

L Series
03

RVD235LN

Demin water

Copper-free brazed solution for refrigerant-to-demineralized-water applications where material compatibility is critical.

R Series
04

JAG F

Central plant

Serviceable plate-and-frame platform for very high flow rates, low approach temperatures and multi-megawatt facility cooling.

JAG F
U.S. footprint

Where data-center demand is concentrated.

Selected U.S. data-center hubs shown on an interactive state map.

CaliforniaSan Jose, Santa Clara, Sacramento
NortheastNew York City, Northern New Jersey
TexasDallas, Austin, San Antonio
U.S. project support

Engineering support from duty point to exchanger selection.

Support for data-center cooling projects where thermal performance, hydraulics, materials and service strategy must work together.

Application engineeringMatch exchanger type and size to duty, fluids, temperatures and pressure-drop limits.
Material and certification fitSelect construction and compliance options for the project specification.
System integrationBalance compactness, approach temperature, pressure drop and maintainability.
Data center team

Talk to our data-center team.

Connect directly with the people supporting data-center and liquid-cooling projects.

Contact

Planning a liquid-cooled data center in the U.S.?

Share the thermal duty, fluids, temperatures, pressure-drop target and available footprint. We will use the operating point to identify a suitable exchanger configuration.